<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-29 17-10-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
6.2 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 65 kHz 6743 0,4004
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,0 dBr 4,82 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 65 kHz MIN: 12 kHz % above 76 kHz: 0,4004 Acquired: 2025/01/29 17.09.50 Total samples: 6743 Equivalent time: 0:05:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 5,9 dBr MIN: 3,0 dBr AVE: 4,82 dBr % above 12,2 dBr: 0,0 Last value: 3,9 dBr (2025/01/29 17.09.50) 16.56 16.58 17.00 17.02 17.04 17.06 17.08 0 2 4 6 Pm [dBr]